enru

UNIFLEX

Code EKN: 000078

Fusion-bonded SBS-modified bitumen-polymer materials. Designed for two-layer / multi-layer roofing systems. They are laid by fusion over the entire surface. Standardized in terms of thickness and breaking characteristics.

Uniflex is made by applying a bitumen-polymer binder containing bitumen, SBS thermoplastic and fillers on a fiberglass or polyester base. Coarse-grained, fine-grained dressing and polymer film are used as a protective layer.

Uniflex material can be used in all climatic regions (according to SP 131.13330.2012 "Construction climatology").

Reviews 9

Roofing materials
Materials laid as a bottom layer
Materials laid as a top layer
Class: Business
Service life: 20-25 years
Flexibility on the timber: -20°С
Package appearance:
Upper side:
Green
Gray
Red
Down side:
Membrane with logo
Physical and mechanical characteristics
Storage and installation method

Scope

Designed for the device of roofing carpet of buildings and structures and waterproofing of building structures.

Grades EKP, TKP, HKP are produced with protective slate dressing and are intended for the device of the upper layer of the roof.

EPP and CCI grades are used for the lower layer of the roof.

Storage:

Rolls should be stored in a closed room or under a canopy at temperatures up to plus 30˚С, sorted by brands, in a vertical position, in one row in height at a distance of at least 1 m from the heating devices.

Installation method

Fusion

Documentation Logistic parameters
Parameter name EPG CCI HPP EKP TCH HKP
Pallet packing White shrink bag
Weight 1 m2, kg 3.8 3.8 3.8 5.0 5.0 5.0
Roll area, m2 10 10 10 10 10 10
Roll weight, kg 38 38 38 50 50 50
Number of rolls per pallet, pcs. 25 25 25 23 23 23
Pallet size, mm 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200
Pallet weight, kg 980 980 980 1180 1180 1180
Equipment and complete assembling
Indicator name EPG CCI HPP EKP TCH HKP
Mass of 1 m2, kg, (± 0.25 kg) 4.0 5.0
Thickness 2.8 3.8
Maximum tensile force, N: along 700 1000 500 700 1000 500
across 500 1100 - 500 1100 -
Binder weight from the side to be welded, kg / m2 2.0
24h Water Absorption 1
Flexibility temperature on the timber R = 25 mm and R = 10 mm, ° С, not higher minus 20
Heat resistance, not less, ° С 100
Length / width, m 10x1
Type of sheeting top film without logo shale
weld-on side film with logo
EKN code 000078 000074 000076 000082 000083 000087

Scope

Designed for the device of roofing carpet of buildings and structures and waterproofing of building structures.

Grades EKP, TKP, HKP are produced with protective slate dressing and are intended for the device of the upper layer of the roof.

EPP and CCI grades are used for the lower layer of the roof.

Storage:

Rolls should be stored in a closed room or under a canopy at temperatures up to plus 30˚С, sorted by brands, in a vertical position, in one row in height at a distance of at least 1 m from the heating devices.

Installation method

Fusion

Parameter name EPG CCI HPP EKP TCH HKP
Pallet packing White shrink bag
Weight 1 m2, kg 3.8 3.8 3.8 5.0 5.0 5.0
Roll area, m2 10 10 10 10 10 10
Roll weight, kg 38 38 38 50 50 50
Number of rolls per pallet, pcs. 25 25 25 23 23 23
Pallet size, mm 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200 1000 × 1200
Pallet weight, kg 980 980 980 1180 1180 1180