enru

TECHNOELAST FLAME STOP

Technoelast FLAME STOP is a surfactant, bitumen-polymer roll roofing material. Technoelast FLAME STOP is obtained by double-sided application on a polyester base of a bitumen-polymer binder consisting of bitumen, SBS (styrene-butadiene-styrene) polymer modifier, mineral filler (talc, dolomite, etc.) and fire retardants, followed by application on both sides of the canvas protective layers. As protective layers, coarse-grained (shale) dressing is used on top and a polymer film on the bottom.

Depending on the type of protective layers and the area of ​​application, Technoelast FLAME STOP produces the following brands:

  • Technoelast FLAME STOP K - with coarse-grained dressing on the front side of the web and polymer film or fine-grained dressing on the underside of the web; it is used for the device of the upper layer of roofing carpet.

Reviews 4

Class: Premium
Flexibility on the timber: -25 ° С
Warranty certificate
Service life: 25-30 years old
Package appearance:
Upper side:
Slate
Down side:
Membrane with logo
Physical and mechanical characteristics
Weight 1 m 2 , kg, (± 0.25 kg)
Technoelast FLAME STOP 5.2
Thickness, mm
Technoelast FLAME STOP 4.2
Breaking force in the longitudinal / transverse direction, N, not less,
Technoelast FLAME STOP 600
Technoelast FLAME STOP 400
Binder weight from the bottom side, not less, kg / m 2
Technoelast FLAME STOP 2.0
Water absorption within 24 hours, no more,% by weight
Technoelast FLAME STOP 1
Flexibility temperature on a bar R = 25 mm, not higher, ° С
Technoelast FLAME STOP -25
Water resistance at a pressure of at least 0.001 MPa,
for 72 hours
Technoelast FLAME STOP absolute
Heat resistance, not less, ° С
Technoelast FLAME STOP 100
Loss of sprinkling *, no more than (g / sample)
Technoelast FLAME STOP 1
Length / width, m
Technoelast FLAME STOP 10x1
Type of sheeting
Top side
Technoelast FLAME STOP slate
Bottom
Technoelast FLAME STOP film with logo
Storage and installation method

Scope

Designed for the device of roofing carpet of buildings and structures. Has increased fire-technical characteristics according to SNiP 21.01: flame spread group RP1 (non-spreading flame); flammability group B2 (moderately flammable).

Storage

Rolls of material should be stored in a dry closed room in a vertical position in one row in height at a distance of at least 1 m from the heaters.

Installation method

Fusion

Documentation Equipment and complete assembling
Parameter name Unit rev. Technoelast FLAME STOP
Mass 1 m 2 , (± 0.25) kg 5.2
Thickness mm 4.2
Tensile breaking strength, not less along N 600
across N 400
Binder weight from the bottom side, not less kg/m2 2.0
Water absorption within 24 hours, no more % by mass 1
Flexibility temperature on the bar R = 25 mm, not higher ° С -25
Water resistance at a pressure of not less than 0.001 MPa, for 72 hours - absolute
Heat resistance, not less ° С 100
Loss of sprinkling *, no more g / sample 1
Length / Width m 10x1
Type of sheeting top - slate
bottom - film with logo

Scope

Designed for the device of roofing carpet of buildings and structures. Has increased fire-technical characteristics according to SNiP 21.01: flame spread group RP1 (non-spreading flame); flammability group B2 (moderately flammable).

Storage

Rolls of material should be stored in a dry closed room in a vertical position in one row in height at a distance of at least 1 m from the heaters.

Installation method

Fusion