TN-ROOF Standard Green
A maintenance roof system with green spaces with standard layouts.
- Soil with green spaces
- PLANTER geo profiled membrane
- Technoelast GREEN
- Technoelast EPPG *
- Bitumen primer TECHNONICOL No. 01
- Reinforced cement-sand screed with a thickness of at least 50 mm
- Slope-forming layer of expanded clay concrete
- Extruded polystyrene foam TECHNONICOL CARBON PROF
- Technobarrier **
- Reinforced concrete base
Alternative materials
* Technoelast FIX
** Bipole EPP | Uniflex EPP | Technoelast ALFA
This system serves as an environmentally friendly and effective protective coating. The role of ballast in this system is soil with green spaces.
The system uses a two-layer waterproof carpet made of fused bitumen-polymer materials Technoelast EPP as the bottom layer and Technoelast GREEN as the top layer. Technoelast GREEN material additionally performs the function of protecting the waterproofing carpet from damage by plant roots. The use of root-resistant materials in green roofs is specified in clause 5.5.2 SP 17.13330.2017.
To ensure the fastest possible removal of excess moisture from the roof surface, arrange a drainage gap from the PLANTER geo profiled membrane. The mechanical strength and reliability of the system is due to the reinforced screed, which is arranged over the slope-forming layer of expanded clay concrete. As the main layer of thermal insulation, a thermal insulation extruded polystyrene foam TECHNONICOL CARBON PROF is used, which is distinguished by high thermal insulation characteristics and increased compressive strength.
As a vapor barrier on a concrete base, the deposited material Technobarrier is used. The technical barrier reliably protects the roofing cake from steam saturation, while being resistant to possible mechanical damage during installation. The flexibility of the material up to minus 20 ° C makes it possible to create a vapor barrier at negative temperatures.
Roofs of residential, administrative and public buildings, including the stylobate part. The system is compatible with the solutions TN-ROOF STANDARD TROTUAR and TN-ROOF STANDARD AUTO.
DESIGN ACCORDING TO:
- STO 72746455-4.1.1-2020 Insulation systems. Roofs with waterproofing carpet made of rolled bitumen-polymer and polymer materials. Technical description. Requirements for design, materials, products and structures;
- Guidelines for the design and installation of roofs made of bitumen-polymer materials;
- Guidelines for the design and construction of maintained and green roofs.
This system serves as an environmentally friendly and effective protective coating. The role of ballast in this system is soil with green spaces.
The system uses a two-layer waterproof carpet made of fused bitumen-polymer materials Technoelast EPP as the bottom layer and Technoelast GREEN as the top layer. Technoelast GREEN material additionally performs the function of protecting the waterproofing carpet from damage by plant roots. The use of root-resistant materials in green roofs is specified in clause 5.5.2 SP 17.13330.2017.
To ensure the fastest possible removal of excess moisture from the roof surface, arrange a drainage gap from the PLANTER geo profiled membrane. The mechanical strength and reliability of the system is due to the reinforced screed, which is arranged over the slope-forming layer of expanded clay concrete. As the main layer of thermal insulation, a thermal insulation extruded polystyrene foam TECHNONICOL CARBON PROF is used, which is distinguished by high thermal insulation characteristics and increased compressive strength.
As a vapor barrier on a concrete base, the deposited material Technobarrier is used. The technical barrier reliably protects the roofing cake from steam saturation, while being resistant to possible mechanical damage during installation. The flexibility of the material up to minus 20 ° C makes it possible to create a vapor barrier at negative temperatures.